Sigrist Measuring Instrument

Manufacturer of a wide range of products which include aquadms measuring instrument, multi-parameter measuring system for water treatment, aquasact s measuring instrument, aquascat wtm-ht-p measuring instrument, oilguard 2- on-line oil in water analyzer and absorption measuring instrument.

AquaDMS Measuring Instrument

AquaDMS Measuring Instrument
  • AquaDMS Measuring Instrument
Ask For Price
Applications Potentiostatic measurement of one of the following parameters Free Chlorine (HClO, hypochloric acid) Chlorine Dioxide (ClO2) Ozone (O3) Hydrogen Peroxide (H2O2)Industries Treatment of drinking water Beverage production Food production Process water in various industries

Innovations with tangible benefits

Complete system A pre-assembled system with the following components depending on the configuration: Intelligent control system Flow regulator Automatic sensor cleaning Sensor to measure disinfectant Sensor to measure pH Mount – connect water – measure.
 Potentiostatic Measurement With this principle, the sensor is in direct contact with the medium to be measured: Measured value available within seconds. No membranes. No electrolyte to be refilled.

 Flow regulator Stable water flow is most critical for the potentiostatic measurement of disinfectants.The flow regulator guarantees: Minimum needed flow stability. Precise measurement during long periods of time.

 Maintenance All sensors are equipped with the automatic sensor cleaning function ASR®. The cleaning interval can be chosen freely andis at least 24 hours: No manual cleaning is necessary. No chemical additives are necessary. Long calibration cycles. ASR® eliminates coatings of organic and inorganic material (limestone, fat,iron- manganese oxides, etc).
 Intelligent control system

 Control unit with touch screen technology and color display. Values, alarm- and status messages canbe presented. MicroSD-card for data storage a
Request
Callback
Yes! I am interested

Multi-Parameter Measuring System for Water Treatment

Multi-Parameter Measuring System for Water Treatment
  • Multi-Parameter Measuring System for Water Treatment
Ask For Price
Specifications:- 

Protection class

min. IP 54

Sample temperature

0 .. +40 °C

Outputs

4 x 0/4 .. 20 mA, galvanic separated
2 x Relays 250 VAC, 4 A
5 x digital outputs, free configurable

Sample pressure

max. 0.6 MPa (6 bar)

Inputs

1 x for optional flow meter
2 x 0/4 .. 20 mA
4 x digital outputs, free configurable

Ambient temperature

0 .. +50 °C

Humidity

0 .. 100% rel. F.

Supply voltage

100 .. 240 VAC, 47 .. 63 Hz or
18 .. 30 VDC

Power input

max. 10 W

Dimensions

approx. 55 x 115 x 40 cm (B x H x T)

Options

Current output module, 4 x 0/4 .. 20 mA
Profibus DP
Modbus RTU

Display

1/4 VGA, 3.5"

Operation

Touchscreen



Applications:

  • Combined measurement of: Turbidity, pH, Conductivity, Redox / ORP, Dissolved oxygen, Temperature
  • 2 additional, external parameters Properties
  • Compact, modular complete system
  • Unrestricted combination of parameters
  • Central, integrated control unit with colour touchscreen
  • Strong, reliable brands: Sigrist Hamilton
  • One partner for all measurements
  • Integration of external sensors possible(e.g. ColorPlus
  • Simple calibration and maintenance without tools Industries
  • Treatment of drinking water
  • Industrial water treatment

Innovations with real benefits:
  • Compact complete system A compact measuring system for a multitude of parameters. Turbidity in all available AquaScat variations, pH, conductivity,redox / ORP, dissolved oxygen, temperature
  • Freely selected and combined parameters
  • Compact footprint
  • Simple installation; only a support has to be mounted
  • Only a water supply and discharge is needed
  • Connect – adjust water flow – measure
  • Modular structure Measuring cell with room for 4 sensors is provided as standard. 2 additional parameters can be integrated via an analogue input (4–20 mA)
  • Initial installation with only one parameter possible
  • Additional sensors can be supplemented at any time
  • SIGRIST ColorPlus for the measurement of DOC (UV absorption) and colour(Hazen) can be combined.
  • Integrated control unit A touch screen with colour display serves as user interface
  • Only one control unit is necessary; this is integrated in the system
  • The display shows either values, graphs,status or alarm messages
  • An internal data logger allows recalling and displaying measured data from the last 32 days
  • Extensive communication options including an integrated web server.
  • User-friendly maintenance Simple maintenance without tools. Storage shelf for calibration liquids, mounting brackets for sensors and the electronic part of the AquaScat
  • Both hands are free to calibrate and to work at the AquaScat
  • Little risk of damage
  • Automatic detection of the sensors‘calibration standards Integrated display of the quality of the sensors
  • Simple replacement of the sensors according to the principle «Plug Measure».
Request
Callback
Yes! I am interested

AquaSact S Measuring Instrument

AquaSact S Measuring Instrument
  • AquaSact S Measuring Instrument
Ask For Price
Applications Turbidity measurement in raw water Monitoring of flucculation and dosage of flocculants Filtration monitoring Turbidity measurement in treated water Turbidity monitoring of water in storage and distribution networks Turbidity measurement in process water Industries Potable water treatment Beverage industry Food production industry Industrial water treatment Characteristics Measurement directly in the water Re-calibration with secondary standard Lowest stray light level, also in heavily reflecting stainless steel tubing Very low maintenance needs Various process connections Various options to present and to transfer the measured data to PLC/SCADA Web interface

Innovations with true customer benefits

Measurement directly in the water Sensor head is sloped: Water flow creates self cleaning effect of the sensor head surface. Zero drift in water with turbidities of max. 1 FNU (without manganese, ironor any other sticking substances) is less than 2% per six months of operation
 The absorber The absorber allows the application of the sensor in all possible process installations: Eliminates stray light form the environment Avoids unwanted influences of the measured values by light reflexions,particularly in stainless steel tubing. Turbidity values of a few mFNU can be measured precisely.

 Re-calibration with secondary standard (Solid glass body)Formazine is used in the factory to calibrate the AquaScat S after assembly. For re-calibration,a secondary standard is available: Precise re-calibration is possible without the use of Formazine. Purchase and storage of Formazine is not needed.

 System integration Various options to visualize and to transfer the data to PLC/SCADA are available:– 8-wire cable– Conn-R and SICON-C– SICON/SICON-M– WLAN Most oft the customer requirements can be covered.

 Process connections Various options for process integration are available: There is a solution for almost every customer requirement.
Request
Callback
Yes! I am interested

AquaScat WTM-HT-P Measuring Instrument

AquaScat WTM-HT-P Measuring Instrument
  • AquaScat WTM-HT-P Measuring Instrument
Ask For Price
Applications Turbidity measurement in raw water Monitoring of flocculation and dosage of flocculants Filtration monitoring of filter performance and back-wash control Turbidity measurement in treated and final waters Turbidity monitoring of water in storage and distribution networks Turbidity measurement in process and waste waters Industries Potable Water Treatment Works Waste water treatment Industrial water production Advantages True non-contact measurement in free-fall stream (models WTM, WTM A, HT) Dual beam measurement in optimized cell(model P) Re-calibration with secondary standard(fully automatic at model WTM A) Lowest stray light levels Virtually maintenance free Convenient operation via touch screen Graphical display of trends and/or values Visualization of measured values over the past month

Innovations with true customer benefits

Non-contact free-fall concept Water passes through the AquaScat models WTM, WTM A and HT without touching the optics. No window fouling and hence, the measured values are not falsified. Very low and high turbidity values can be measured precisely. The entire sample beam is measured which leads to true representative results. Extremely low maintenance is the result.
 Dual beam concept At the AquaScat P, transmitted light and scattered light are measured and taken into consideration. The cell is large and the machining is of high quality. The influence of the cell contamination is reduced substantially. Possible interference by colour is completely eliminated. Cell cleaning is minimised.

 Very low quantity of stray light The design of the AquaScat in combination with high quality optical components minimizes the quantity of stray light inside. A stable measurement of a few mFNU turbidity is therefore possible. Very low zero drift provides excellent long term stability.
 Re-calibration with secondary standard Formazine is used in the factory to calibrate the AquaScat after assembly. For re-calibration,a secondary standard (Zerodur®glass body) is available. Precise re-calibration is possible without the use of Formazine. In the AquaScat WTM A, this re-calibration is done automatically without stopping the water flow.

 Integrated control unit The control unit of all the AquaScat family is an integrated colour touch screen. Values, graphs, alarm- and status messages can be presented. An internal data logger allows recalling and displaying measured data of the last 32 days.
Request
Callback
Yes! I am interested

OilGuard 2- On-line Oil in Water Analyzer

OilGuard 2- On-line Oil in Water Analyzer
  • OilGuard 2- On-line Oil in Water Analyzer
Ask For Price
Applications: Oil traces in raw water Oil trace monitoring in boiler water and condensate Oil trace monitoring in heat exchanger Effluent water monitoring Storm water monitoring Industries Power plants Water treatment plants Oil industry Advantages Well-proven UV-Fluorescence measuring principle True non-contact measurement in a free-fall stream Dual-beam optics for highest accuracy and stability Integrated operation panel with touch screen,color display and data logger Flexible, modular system Fast recalibration with checking unit Minimum maintenance requirements Correlates to any International recognized standard reference method On-line Oil in Water Analyzer Oil Guard Innovations with real benefits: Modular design Three different measuring cells are availableto suit application specific requirements Closed flow cell for clean water andcondensate Free-fall measuring cell in stainless steel316L or PVDF for dirty water.Optional accessories Wall mounting rack, big rack Sample preparation system Integrated sampling kit for QC purpose. Lowest cost of ownership Negligible maintenance SIGRISTs well-proven true non-contact measuring concept prevents the entire system from soiling. This leads into an amazing long maintenance interval No ultrasonic cleaning device is needed The negligible maintenance is quick and easy, no special tools are required. Reliable measurement The instrument uses a sophisticated dual beam optical setup with optimized wave length configuration Guarantees highest accuracy and stability of the measurement Automatically compensates fluctuations and light source ageing The relevant HC components are measured Reduces the impact of solids. Quick verification of the measurement The verification and recalibration of the instrument is performed quickly by using a unique solid reference (secondary standard)from SIGRIST No chemicals are needed for the calibration or cleaning No special tools are required. Integrated control unit The control unit in the Oil Guard is based on an integrated colour touch screen Values, graphs, alarm- and status messages can be presented An internal data logger allows recalling and displaying measured data from the last 32 days
Request
Callback
Yes! I am interested

Absorption Measuring Instrument

Absorption Measuring Instrument
  • Absorption Measuring Instrument
Ask For Price
Specifications:- 

Measuring principle

Absorption

Nominal range

0 .. 3 E

Scale ranges

8 ranges, freely configurable

Resolution

0.001 E

Flow cell material

Stainless steel 316L, Titanium, Hastelloy, PVDF, etc.

Ambient temperature

-20 .. +50 °C

Flow cells

Varivent®, custom-specific

Wavelengths UV

254, 313, 365, 436, 546 nm

Wavelengths VIS

365, 380 .. 700 nm


Applications:

  • DOC (UV absorption) measurement
  • Colour (Hazen) measurement Measurement of the elimination of micropollutants Industries
  • Treatment of drinking water
  • Waste water treatment
  • Process water in various industries

Properties:
  • Combined online measurement of DOC(UV absorption) and colour (Hazen) in one instrument
  • Optical compensation of window soiling
  • Dual beam measurement for high stability
  • Flow cell easy to clean without tools
  • Fast and simple verification with control unit
  • Turbidity compensation by means of an additional light source (optional)

Innovations with tangible benefits
  • Multiple device configurations
  • Up to three light sources can be installed in the instrument. This allows simultaneous measurement of DOC (UV absorption)and colour (Hazen) and compensation of turbidity
  • Two measurements are available in one instrument
  • The real colour is measured
  • DOC (UV absorption) is measured without the influence of turbidity.
  • Flow cell and cover with screws The cover of the flow cell can be opened without tools
  • Allows simple access for cleaning the flow cell
  • Cleaning involves little effort.
  • Compensation glass Soiling of the flow cell is measured by means of a compensation glass in the interior of the flow cell
  • The effect of cell soiling is greatly reduced internally
  • Constant and precise measured values are guaranteed
  • The user is alerted if the cell has to be cleaned.
  • Checking unit For inspecting the instrument, checking units on the basis of reference filters can easily be inserted
  • A checking unit is included in the basic configuration and allows the checking of high absorption
  • Further checking units are available for checking various measuring points.
  • Intelligent Control System The SICON control unit with state-of-the art touch screen technology and colour display
  • Values, graphs, alarm and status messages can be presented
  • An internal data logger allows recalling and displaying measured data from the last 32 days.
Request
Callback
Yes! I am interested

Automatic Flow Cytometer

Automatic Flow Cytometer
  • Automatic Flow Cytometer
Ask For Price
Specifications:-

Measuring principle

Flow cytometry

Side scatter

488/10 (SSC)

Wavelength

Laser diode 488 nm

Nominal range

1 x 103 .. 1 x 106 cells/ml

Detection limit

1 x 102 cells/ml

Bacteria Metrics

LNA/ml, HNA/ml, HNAP (%)

Cartridge capacity

1'000 measurements



Applications:

  • Bacteriological measurement of the total cell number
  • Determination of the size ratio of the bacteria(LNA/HNA)
  • Wherever a fast answer concerning the microbiological quality and stability of the drinking water is required
  • Disinfection control (chlorination, ozonisation)
  • Online process monitoring
  • Monitoring of the water distribution network in case of contamination, cleaning/flushing
  • Monitoring of home installations
  • Rapid bacteriological contamination detection Industries
  • Drinking water treatment
  • Drinking water distribution

Advantages:
  • Fully automated Flow Cytometer specifically designed for the requirements in the drinking water industry
  • Result available after 30 minutes
  • Simple handling based on cartridge system
  • User friendly operation and maintenance concept
  • Compact instrument with a low foot print
  • Easy system integration thanks to extensive interfaces
  • Detection of more than 99% of bacteria
  • Favourable cost of ownership

Innovations with tangible benefits:
  • Fully automatic system The whole program sequence, sampling – adding of reagents – mixing – incubation – measurement – cleaning is performed fast and fully automatically
  • All manual preparation steps are eliminated, therefore no specially trained staffs required
  • The whole program sequence only takes 30 minutes
  • Allows continuous measurement also in remote areas.
  • Simple cartridge concept All chemicals, including waste, are packed in a hermetical closed, recyclable cartridge. One car-tridge is sufficient for 1‘000 measurements
  • Purchases, logistics, handling of chemicals and waste disposal have been easy resolved
  • The exchange of the cartridge is as easy as the replacement of an ink cartridge in a printer
  • Economic thanks to the use of recyclable cartridges.Intelligent operating unit A large touch screen with colour display serves as a control unit
  • Control unit is integrated in the system
  • An automatic and a manual mode allow simple and clear operation
  • An internal data base allows recalling and displaying measured data from previous years
  • Extensive communication options including an integrated web interface.
  • User friendly maintenance concept The instrument is constructed in a way which only needs one scheduled maintenance per year. This work will be carried out by a qualified SIGRIST representative for a fix price
  • High availability; maintenance can be planned
  • Transparent cost for maintenance and operation which can be calculated in advance
  • Verification of the calibration can be done by the operator at any
Request
Callback
Yes! I am interested
X
Looking for “Sigrist Measuring Instrument”?


Reach Us
Sujit (Director)
TA-01, Third Floor, A Wing, Lake City Mall, Kapurbawdi Junction GB Road, Thane West, Above Mc Donalds, Kapurbawdi Naka
Thane- 400607, Maharashtra, India


Call Us

Send E-mail

Send SMS